AXIS I/O Module
This guide covers the installation, configuration, and operation of the Irisity Digital I/O integration. The integration supports AXIS D3110 Connectivity Hub.
![Document image Document image](https://images.archbee.com/JzHznijrWxPLJLDUaV5A1/WV_uPpm-CJ9EWKYy8o7Ap_image.png?format=webp)
The Axis module contains configurable input ports. Changes in Digital Input state (i.e., opening or closing the circuits) can activate or de-activate analytics rules in IRIS+. A typical use case is using an external alarm system that is activated at the end of a business day, which should then activate the analytics rules in IRIS+ The IRIS+ Digital IO Gateway service runs on the IRIS+ Edge device, communicates with the Axis module, and responds to signals from the module input ports to affect analytics rules.
The Axis module can be added to any IRIS+ Edge device in your IRIS+ account. Once added, it can be set up to control any rule on any folder or camera in your account. In the following example, we use an Axis P8221 module with 4 Input ports ( A 1, 2, 3, 4). Port #1 is set to Active:
![Document image Document image](https://images.archbee.com/JzHznijrWxPLJLDUaV5A1/XWCB8-ihuHbFNkRv2Py5j_image.png?format=webp)
- Select Physical View
- Select the relevant Edge Device
- Select Digital IO
- Select Add Device:
- Populate the following credentials to the Axis module:
- Device Name
- Host
- Port (default is 80)
- User
- Password
- Select Save
The IRIS+ Edge device disconnects for a few seconds and reconnects. The following window appears:
![Document image Document image](https://images.archbee.com/JzHznijrWxPLJLDUaV5A1/qnw9inY141uSO7PBCppeA_image.png?format=webp)
- Select Edit
- The Input ports mapping section is now editable:
Select the relevant values for each port line as follows:
Field Name | Possible Values | Meaning |
Type |
| |
Entity | As available | Folder name or Camera name as applicable following the Type selection |
Rule |
| The rule/s which will be activated/deactivated upon port state change |
On High |
| When port is active (green) defines what action will be applied to the selected rule/s |
On Low |
| When port is inactive (red): defines what action will be applied to the selected rule/s |
- Select Save
Note: if a Schedule and/or Calendar definition exists for any of the selected rules, the defined action for overrides the Schedule and/or Calendar definition.